Back to Search Start Over

Automated control of Impella maintains optimal left ventricular unloading during periods of unstable hemodynamics and prevents myocardial damage in acute myocardial infarction.

Authors :
Nishikawa, Takuya
Kamada, Kazuhiro
Morita, Hidetaka
Matsushita, Hiroki
Yokota, Shohei
Sato, Kei
Unoki, Takashi
Tsutsui, Hiroyuki
Sunagawa, Kenji
Saku, Keita
Source :
International Journal of Cardiology. Sep2024, Vol. 410, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

Left ventricular (LV) unloading by Impella, an intravascular microaxial pump, has been shown to exert dramatic cardioprotective effects in acute clinical settings of cardiovascular diseases. Total Impella support (no native LV ejection) is far more efficient in reducing LV energetic demand than partial Impella support, but the manual control of pump speed to maintain stable LV unloading is difficult and impractical. We aimed to develop an Automatic IMpella Optimal Unloading System (AIMOUS), which controls Impella pump speed to maintain LV unloading degree using closed-feedback control. We validated the AIMOUS performance in an animal model. In dogs, we identified the transfer function from pump speed to LV systolic pressure (LVSP) under total support conditions (n = 5). Using the transfer function, we designed the feedback controller of AIMOUS to keep LVSP at 40 mmHg and examined its performance by volume perturbations (n = 9). Lastly, AIMOUS was applied in the acute phase of ischemia-reperfusion in dogs. Four weeks after ischemia-reperfusion, we assessed LV function and infarct size (n = 10). AIMOUS maintained constant LVSP, thereby ensuring a stable LV unloading condition regardless of volume withdrawal or infusion (±8 ml/kg from baseline). AIMOUS in the acute phase of ischemia-reperfusion markedly improved LV function and reduced infarct size (No Impella support: 13.9 ± 1.3 vs. AIMOUS: 5.7 ± 1.9%, P < 0.05). AIMOUS is capable of maintaining optimal LV unloading during periods of unstable hemodynamics. Automated control of Impella pump speed in the acute phase of ischemia-reperfusion significantly reduced infarct size and prevented subsequent worsening of LV function. [Display omitted] • We have developed an Automated IMpella Optimal Unloading System (AIMOUS). • AIMOUS controls LV unloading degree using closed-feedback control. • AIMOUS maintained constant LVSP regardless of volume withdrawal or infusion. • AIMOUS in AMI markedly improved LV function and reduced infarct size compared with no Impella support group. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01675273
Volume :
410
Database :
Academic Search Index
Journal :
International Journal of Cardiology
Publication Type :
Academic Journal
Accession number :
178069310
Full Text :
https://doi.org/10.1016/j.ijcard.2024.132244