Back to Search Start Over

Bacteriuria and phenotypic antimicrobial susceptibility testing in 45 min by point-of-care Sysmex PA-100 System: first clinical evaluation.

Authors :
Alonso-Tarrés, Carles
Benjumea Moreno, Carla
Navarro, Ferran
Habison, Aline C.
Gonzàlez-Bertran, Elisenda
Blanco, Francisco
Borràs, Jaume
Garrigó, Montserrat
Saker, Jarob
Source :
European Journal of Clinical Microbiology & Infectious Diseases. Aug2024, Vol. 43 Issue 8, p1533-1543. 11p.
Publication Year :
2024

Abstract

Purpose: This study compared the results of the new Sysmex PA-100 AST System, a point-of-care analyser, with routine microbiology for the detection of urinary tract infections (UTI) and performance of antimicrobial susceptibility tests (AST) directly from urine. Methods: Native urine samples from 278 female patients with suspected uncomplicated UTI were tested in the Sysmex PA-100 and with reference methods of routine microbiology: urine culture for bacteriuria and disc diffusion for AST. Results: The analyser delivered bacteriuria results in 15 min and AST results within 45 min. Sensitivity and specificity for detection of microbiologically confirmed bacteriuria were 84.0% (89/106; 95% CI: 75.6–90.4%) and 99.4% (155/156; 95% CI: 96.5–100%), respectively, for bacterial species within the analyser specifications. These are Escherichia coli, Klebsiella pneumoniae, Proteus mirabilis, Enterococcus faecalis and Staphylococcus saprophyticus, which are common species causing uncomplicated UTI. Overall categorical agreement (OCA) for AST results for the five antimicrobials tested in the Sysmex PA-100 (amoxicillin/clavulanic acid, ciprofloxacin, fosfomycin, nitrofurantoin and trimethoprim) ranged from 85.4% (70/82; 95%CI: 75.9–92.2%) for ciprofloxacin to 96.4% (81/84; 95% CI: 89.9–99.3%) for trimethoprim. The Sysmex PA-100 provided an optimal treatment recommendation in 218/278 cases (78.4%), against 162/278 (58.3%) of clinical decisions. Conclusion: This first clinical evaluation of the Sysmex PA-100 in a near-patient setting demonstrated that the analyser delivers phenotypic AST results within 45 min, which could enable rapid initiation of the correct targeted treatment with no further adjustment needed. The Sysmex PA-100 has the potential to significantly reduce ineffective or unnecessary antibiotic prescription in patients with UTI symptoms. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09349723
Volume :
43
Issue :
8
Database :
Academic Search Index
Journal :
European Journal of Clinical Microbiology & Infectious Diseases
Publication Type :
Academic Journal
Accession number :
178527516
Full Text :
https://doi.org/10.1007/s10096-024-04862-3