Time history evaluation assessment of flat slab and conventional slab with framed tube system.
- Source :
-
AIP Conference Proceedings . 2024, Vol. 3146 Issue 1, p1-11. 11p. - Publication Year :
- 2024
-
Abstract
- To analyze time history in order to assess seismic demand for flat slab structures with drops and typical slab structures made of ordinary reinforced concrete. When examining the effect of these slabs on a 30-story structure, quake zone(v) is going to be put into account. It's a sort of linear dynamic evaluation where the structure's strength is evaluated up to its elastic limit. In this study, framed tubes and high-rise buildings with a combined size of 1296 square meters that are susceptible to seismic loading are analyzed throughout time using the ETABS programme. Studying and comparing flat slab buildings with framed tubes to conventional slabs involves looking at certain dynamic parameters. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 0094243X
- Volume :
- 3146
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- AIP Conference Proceedings
- Publication Type :
- Conference
- Accession number :
- 178559750
- Full Text :
- https://doi.org/10.1063/5.0224705