Back to Search Start Over

Analysis of flat slabs with and without drop in different seismic zones using ETABS.

Authors :
Kumar, Gandhemalle Pavan
Kandoori, Roja
Saduwale, Shrihari
Source :
AIP Conference Proceedings. 2024, Vol. 3146 Issue 1, p1-6. 6p.
Publication Year :
2024

Abstract

We all know that a flat slab is sort of slab in the structure don't possess beams. Straight from the slabs, the load is carried to the columns. To withstand shear, a long section of the slab known as the Drop is offered. In comparison to traditional slabs, a flat slab is more affordable. There is a tonne of preserved material. The goal of study is to present a cross-section of structural elements that can meet the stability requirements of IS standards. The primary goal of this effort is to identify the structural components that are cost-effective for G+10 structures in various seismic zones. With the help of the CSI ETABS 2018 software, the building models are examined. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
3146
Issue :
1
Database :
Academic Search Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
178559751
Full Text :
https://doi.org/10.1063/5.0224706