Back to Search Start Over

Effects of temperature on plant growth and arsenic removal efficiency of Pteris vittata in purifying arsenic-contaminated water in winter: A two-year year-round field study.

Authors :
Kohda, Yi Huang-Takeshi
Miyauchi, Keisuke
Rahman, Farzana
Naruse, Haruki
Mito, Mitsuaki
Kitajima, Nobuyuki
Chien, Mei-Fang
Endo, Ginro
Inoue, Chihiro
Source :
Chemosphere. Aug2024, Vol. 362, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

Phytoremediation is a cost-effective and eco-friendly alternative method for arsenic (As) contaminated water treatment. This study conducted a two-year year-round field study (cycle1 and cycle2) in a temperate area (Sendai, Japan) using small As-hyperaccumulator Pteris vittata seedlings to reduce pre-cultivation time and associated costs. The number of seedlings was changed from 256 in the cycle1 period to 165 in the cycle2 period to evaluate the As removal efficiency of P. vittata for As-contaminated water in field conditions with different plant densities. Before the winter season, with continuously increasing fronds, rhizomes, and roots growth, this reduction did not affect the plant's As removal efficiency for As-contaminated water to decrease the As concentration from 30 μg/L to the environmental quality standard for As in water, set at 10 μg/L in Japan. During the winter season, we found that cold weather caused P. vittata to wither and release the accumulated As into water without a greenhouse (cycle1). In the meantime, the bioaccumulation factor (BAF) and the translocation factor (TF) values for fronds of P. vittata decreased (BAF for fronds: from 66,089 to 8,460; TF for fronds: from 13.4 to 3.4). On the other hand, with greenhouse protection (cycle2), P. vittata did not severely wither and kept accumulating As. Moreover, BAF and TF values for fronds of P. vittata increased (BAF for fronds: from 24,372 to 36,740; TF for fronds: from 5.2 to 17.2). Maintaining the air temperature inside the greenhouse, particularly around the rhizomes, above 0 °C may be the reason why P. vittata remained alive and functional during the cold winter. These results indicate that a single-layer polyethylene greenhouse was sufficient for the tropical-subtropical As-hyperaccumulator fern P. vittata to survive the cold winter and snow in the temperate area, enabling year-round phytoremediation treatment of As-contaminated water in the open field. [Display omitted] • Year-round As-phytoremediation for water treatment in temperate area was conducted. • Small seedlings of P. vittata were used in this two-year field study to lower the cost. • As removal efficiency increased with the growth of seedlings before the winter season. • P. vittata released the accumulated As into water without a greenhouse in winter. • Greenhouse protected P. vittata from As efflux and kept accumulating As in winter. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00456535
Volume :
362
Database :
Academic Search Index
Journal :
Chemosphere
Publication Type :
Academic Journal
Accession number :
178811599
Full Text :
https://doi.org/10.1016/j.chemosphere.2024.142902