Back to Search
Start Over
Comparison of PSO and TLBO optimizing techniques for better performance of multilevel inverters.
- Source :
-
AIP Conference Proceedings . 2024, Vol. 3044 Issue 1, p1-9. 9p. - Publication Year :
- 2024
-
Abstract
- This paper presents the comparison ofselective harmonic elimination in a cascaded h-bridge multilevel (CHBMLI) inverter using PSO and TLBO optimization algorithms. The inverters are employed in a variety of applications, including high-voltage dc transmission, variable drive systems, and electrical vehicles. The inverter's output includes harmonics. PSO and TLBO algorithm is used in this paper To find out the best switching angles for a CHBMLI selective harmonic elimination. In order to get the appropriate fundamental component and get rid of low-order harmonics, this project solves nonlinear equations. These algorithms can produce the most effective triggering pulses to minimize Overall Harmonic Distortion(THD) and Selected Harmonics. If the harmonics are removed, the inverter's output will be improved. MATLAB is used to implement and compared both optimization techniques usingthe seven-level inverter. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 0094243X
- Volume :
- 3044
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- AIP Conference Proceedings
- Publication Type :
- Conference
- Accession number :
- 178879433
- Full Text :
- https://doi.org/10.1063/5.0209094