Electrochemical Determination of Imidacloprid Using an Electrosynthesized Hexa-Peri-Hexabenzocoronene Modified Glassy Carbon Electrode (GCE) by Differential Pulse Voltammetry (DPV).
- Source :
-
Analytical Letters . 2024, Vol. 57 Issue 18, p3103-3114. 12p. - Publication Year :
- 2024
-
Abstract
- Hexa-peri-hexabenzocoronene (HBC) modified glassy carbon electrodes (HBC/GCEs) was fabricated by an electrochemical synthesis, solving the difficulty of the preparation of HBC films because of its poor solubility. HBC/GCE was used as a sensing electrode for the voltammetric investigation of imidacloprid (IDP). The presence of HBC increased the conductivity of GCE, and showed good electrocatalytic activity toward the reaction of IDP. Therefore, the HBC enhanced the electrochemical signal of IDP, which increased the sensitivity of the sensor. The best performance was obtained by optimizing the electrochemical synthesis time, pH and enrichment time. The linear response range and the limit of detection were 5 to 750 μmol·L−1 and 1.5 μmol·L−1, respectively. Moreover, the proposed sensor also exhibited good repeatability, selectivity and stability, and promising applications for real sample. [ABSTRACT FROM AUTHOR]
- Subjects :
- *DETECTION limit
*VOLTAMMETRY
*CARBON electrodes
*SOLUBILITY
*ELECTRODES
*DETECTORS
Subjects
Details
- Language :
- English
- ISSN :
- 00032719
- Volume :
- 57
- Issue :
- 18
- Database :
- Academic Search Index
- Journal :
- Analytical Letters
- Publication Type :
- Academic Journal
- Accession number :
- 179805957
- Full Text :
- https://doi.org/10.1080/00032719.2024.2310640