Back to Search
Start Over
Clinical evaluation of the convolutional neural network-based automatic delineation tool in determining the clinical target volume and organs at risk in rectal cancer radiotherapy.
- Source :
-
Oncology Letters . Nov2024, Vol. 28 Issue 5, p1-10. 10p. - Publication Year :
- 2024
-
Abstract
- Delineating the clinical target volume (CTV) and organs at risk (OARs) is crucial in rectal cancer radiotherapy. However, the accuracy of manual delineation (MD) is variable and the process is time consuming. Automatic delineation (AD) may be a solution to produce quicker and more accurate contours. In the present study, a convolutional neural network (CNN)-based AD tool was clinically evaluated to analyze its accuracy and efficiency in rectal cancer. CT images were collected from 148 supine patients in whom tumor stage and type of surgery were not differentiated. The rectal cancer contours consisted of CTV and OARs, where the OARs included the bladder, left and right femoral head, left and right kidney, spinal cord and bowel bag. The MD contours reviewed and modified together by a senior radiation oncologist committee were set as the reference values. The Dice similarity coefficient (DSC), Jaccard coefficient (JAC) and Hausdorff distance (HD) were used to evaluate the AD accuracy. The correlation between CT slice number and AD accuracy was analyzed, and the AD accuracy for different contour numbers was compared. The time recorded in the present study included the MD time, AD time for different CT slice and contour numbers and the editing time for AD contours. The Pearson correlation coefficient, paired-sample t-test and unpaired-sample t-test were used for statistical analyses. The results of the present study indicated that the DSC, JAC and HD for CTV using AD were 0.80±0.06, 0.67±0.08 and 6.96±2.45 mm, respectively. Among the OARs, the highest DSC and JAC using AD were found for the right and left kidney, with 0.91±0.06 and 0.93±0.04, and 0.84±0.09 and 0.88±0.07, respectively, and HD was lowest for the spinal cord with 2.26±0.82 mm. The lowest accuracy was found for the bowel bag. The more CT slice numbers, the higher the accuracy of the spinal cord analysis. However, the contour number had no effect on AD accuracy. To obtain qualified contours, the AD time plus editing time was 662.97±195.57 sec, while the MD time was 3294.29±824.70 sec. In conclusion, the results of the present study indicate that AD can significantly improve efficiency and a higher number of CT slices and contours can reduce AD efficiency. The AD tool provides acceptable CTV and OARs for rectal cancer and improves efficiency for delineation. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 17921074
- Volume :
- 28
- Issue :
- 5
- Database :
- Academic Search Index
- Journal :
- Oncology Letters
- Publication Type :
- Academic Journal
- Accession number :
- 180068273
- Full Text :
- https://doi.org/10.3892/ol.2024.14672