Back to Search Start Over

静电纺丝聚偏氟乙烯压电仿生骨膜的生物相容性评价.

Authors :
赵帅
李冬瑶
魏岁艳
曹怡静
许燕
徐国强
Source :
Chinese Journal of Tissue Engineering Research / Zhongguo Zuzhi Gongcheng Yanjiu. Feb2025, Vol. 29 Issue 4, p730-737. 8p.
Publication Year :
2025

Abstract

BACKGROUND: Our previous studies have found that poly(vinylidene fluoride) bionic periosteum prepared by electrospinning has good cytocompatibility, but its biocompatibility is unknown. OBJECTIVE: To evaluate the biocompatibility of poly(vinylidene fluoride) bionic periosteum doped with Zn2+ and Mg2+. METHODS: Poly(vinylidene fluoride), poly(vinylidene fluoride) bionic periosteum doped with 1% Zn2+, doped with 1% Mg2+, and doped with 1% (Zn2++Mg2+) were prepared by electrospinning to make bionic periosteum extract. SD rats were selected as the experimental subjects for hemolysis test, short-term systemic toxicity test, and heat source test. Guinea pigs were selected as the experimental subjects for skin sensitization test. The biocompatibility of bionic periosteum of four groups was tested. RESULTS AND CONCLUSION: (1) The hemolysis test results showed that the hemolysis rates of 1% Zn2+ poly(vinylidene fluoride), 1% Mg2+ poly (vinylidene fluoride), 1% Zn2++1% Mg2+ poly(vinylidene fluoride) bionic periosteum and poly(vinylidene fluoride) extract were (0.130±0.013)%, (0.149±0.020)%, (0.466±0.018)%, and (0.037±0.018)%, respectively, which met the hemocompatibility standard of biomaterials. (2) The results of short-term systemic toxicity test showed that the four groups of bionic periosteal extract had no toxic signs such as body mass reduction, food intake changes, and dyspnea in SD rats, and had no toxic effects on major organs of rats. (3) Heat source test results showed that after intervention with poly(vinylidene fluoride) bionic periosteum doped with 1% Zn2+, doped with 1% Mg2+, and doped with 1% (Zn2++Mg2+), and poly(vinylidene fluoride) bionic periosteum extract, the elevated body temperature values of SD rats were (0.133±0.058), (0.100±0.010), (0.300±0.010), and (0.300±0.017)°C, respectively. All were less than 0.6 °C, and the total temperature increase was less than 1.4*#176;C. (4) The results of skin sensitization test showed that no erythema or edema was observed under the skin of guinea pigs after the intervention of bionic periosteum extract of four groups. (5) The results showed that poly(vinylidene fluoride) and poly(vinylidene fluoride) bionic periosteum doped with Zn2+ and Mg2+ had good biocompatibility. [ABSTRACT FROM AUTHOR]

Details

Language :
Chinese
ISSN :
20954344
Volume :
29
Issue :
4
Database :
Academic Search Index
Journal :
Chinese Journal of Tissue Engineering Research / Zhongguo Zuzhi Gongcheng Yanjiu
Publication Type :
Academic Journal
Accession number :
180222548
Full Text :
https://doi.org/10.12307/2025.257