Back to Search Start Over

A More Efficient and Safer Improved Percutaneous Pedicle Screw Insertion Technique—Trajectory Dynamic Adjustment Technique, Technical Note, and Clinical Efficacy.

Authors :
Li, Hao
Ding, Zhiguo
Wei, Bin
Ma, Zhihao
Xie, Jing
Tian, Yonghao
Wang, Lianlei
Liu, Xinyu
Yuan, Suomao
Source :
Orthopaedic Surgery. Oct2024, p1. 12p. 7 Illustrations.
Publication Year :
2024

Abstract

ABSTRACT Objective Method Results Conclusion Percutaneous pedicle screw fixation (PPSF) technique requires a very precise entry point of the Jamshidi needle, which leads to repeated adjustments, damaging the pedicle and increasing radiation exposure. This study was designed to propose an improved percutaneous pedicle screw fixation technique‐trajectory dynamic adjustment (TDA) technique, and evaluate its feasibility and assess the clinical outcomes.A total of 445 patients with lumbar spondylolisthesis or lumbar spinal stenosis associated with instability from June 2017 to May 2022 were included in the retrospective study. They were randomly separated into two groups. Two hundred thirty‐one patients underwent TDA technique (TDA group). Two hundred fourteen patients underwent traditional PPSF technique (PPSF group). All patients underwent postoperative CT to assess the accuracy of screw placement, superior facet joint violation (FJV). The evaluated clinical outcomes were needle insertion time, radiation exposure, blood loss, hospital stay, the Japanese Orthopedic Association (JOA) score, the Visual Analogue Scale (VAS) scores for lower back pain (LBP), and leg pain, lumbar interbody fusion rate, and postoperative complications. The independent‐sample t test and paired t‐test were used for continuous data. The contingency table and Mann–Whitney U test were used for categorical data.The time of the insertion in TDA group was significantly lower than that in PPSF group (p < 0.05). Similarly, the fluoroscopy frequency in TDA group was significantly lower than that in PPSF group (p < 0.05). There was no difference in intraoperative blood loss and hospital stay between the two groups (p > 0.05). Overall, there was no significant difference in the proportion of clinically acceptable screws between the two groups (p > 0.05). In addition, the lateral screw misplacement in TDA group was higher. Moreover, FJV rate was significantly lower than that in PPSF group (p < 0.05). In both TDA group and PPSF group, postoperative back and leg pain and the JOA score were significantly improved (p < 0.05). However, there were no significant differences in the pre‐ and postoperative VAS score for back and leg pain and the JOA score, JOA recovery rate, intervertebral fusion rate, and complications rate between the two groups (p > 0.05).Compared to traditional PPSF technique, TDA technique is a safer and more effective procedure which has shorter surgical time, lower radiation exposure, and lower facet joint violation rate. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
17577853
Database :
Academic Search Index
Journal :
Orthopaedic Surgery
Publication Type :
Academic Journal
Accession number :
180265329
Full Text :
https://doi.org/10.1111/os.14260