Back to Search
Start Over
Multi-assessed green sustainable chromatographic resolution of nicotine and caffeine; application to in-vitro release from a new quick mist mouth spray co-formula.
- Source :
-
BMC Chemistry . 10/15/2024, Vol. 18 Issue 1, p1-13. 13p. - Publication Year :
- 2024
-
Abstract
- The availability of well-established analytical methods is crucial to cope with the fast-ongoing research for the development of new drug delivery formulations. In this work, a rapid highly green chromatographic method was developed for the simultaneous determination of nicotine (NIC) and caffeine (CAF) to be applied for an in-vitro release study from a newly prepared quick mist mouth spray co-formula (QMS), as a complementary synergistic fast-onset relief of cravings during smoking cessation. The chromatographic resolution was accomplished on a cyano column using isocratically delivered (1.0 mL/ min) glycerol: orthophosphoric acid (OPA) (0.2 M) adjusted to pH 3.0 using 0.05 M triethylamine (5:95, v/v) and UV detection at 260 nm. Well resolved peaks of NIC and CAF were eluted at 2.1 and 3.9 min (Rs = 5.64), with linear responses between 0.1 and 20.0 µg/mL and 0.2–40.0 µg/mL, and detection limits of 0.03 and 0.07 µg/mL for NIC and CAF, respectively. The developed method showed good analytical performance (accuracy, precision, robustness, and selectivity) as well as superiority in practicality and ecological profile compared to reported methods applying GAPI, analytical eco-scale, AGREE, BAGI, and whiteness metric tool. The developed method was successfully applied for NIC and CAF determination in their pharmaceutical preparations, and artificial saliva with no significant differences from reported method results (F-test and t-test). Moreover, an in-vitro release study of NIC and CAF from QMS was performed employing the developed method that revealed diffusion-controlled release, compared to mixed diffusion/ polymer chain relaxation for marketed single component formulation, showing the superiority of QMS in reducing drug level fluctuations of NIC and CAF and improving their bioavailability. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 2661801X
- Volume :
- 18
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- BMC Chemistry
- Publication Type :
- Academic Journal
- Accession number :
- 180269344
- Full Text :
- https://doi.org/10.1186/s13065-024-01306-z