Back to Search Start Over

Cost effectiveness of commercial portable ex vivo lung perfusion at a low‐volume US lung transplant center.

Authors :
Kent, Johnathan
Nordgren, Rachel
Ahn, Daniel
Lysandrou, Maria
Diaz, Ashley
Fenton, David
Wignakumar, Thirushan
McMeekin, Nicola
Salerno, Christopher
Donington, Jessica
Madariaga, Maria Lucia L.
Source :
Artificial Organs. Nov2024, Vol. 48 Issue 11, p1288-1296. 9p.
Publication Year :
2024

Abstract

Background: Portable ex vivo lung perfusion during lung transplantation is a resource‐intensive technology. In light of its increasing use, we evaluated the cost‐effectiveness of ex vivo lung perfusion at a low‐volume lung transplant center in the USA. Methods: Patients listed for lung transplantation (2015–2021) in the United Network for Organ Sharing database were included. Quality‐of‐life was approximated by Karnofsky Performance Status scores 1‐year post‐transplant. Total transplantation encounter and 1‐year follow‐up costs accrued by our academic center for patients listed from 2018 to 2021 were obtained. Cost‐effectiveness was calculated by evaluating the number of patients attaining various Karnofsky scores relative to cost. Results: Of the 13 930 adult patients who underwent lung transplant in the United Network for Organ Sharing database, 13 477 (96.7%) used static cold storage and 453 (3.3%) used ex vivo lung perfusion, compared to 30/58 (51.7%) and 28/58 (48.3%), respectively, at our center. Compared to static cold storage, median total costs at 1 year were higher for ex vivo lung perfusion ($918 000 vs. $516 000; p = 0.007) along with the cost of living 1 year with a Karnofsky functional status of 100 after transplant ($1 290 000 vs. $841 000). In simulated scenarios, each Karnofsky‐adjusted life year gained by ex vivo lung perfusion was 1.00–1.72 times more expensive. Conclusions: Portable ex vivo lung perfusion is not currently cost‐effective at a low‐volume transplant centers in the USA, being 1.53 times more expensive per Karnofsky‐adjusted life year. Improving donor lung and/or recipient biology during ex vivo lung perfusion may improve its utility for routine transplantation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0160564X
Volume :
48
Issue :
11
Database :
Academic Search Index
Journal :
Artificial Organs
Publication Type :
Academic Journal
Accession number :
180279647
Full Text :
https://doi.org/10.1111/aor.14816