Abstract
- A pilot-scale investigation of ozonation combined with electrolysis (E-O3) was performed to treat concentrated wastewater from a reverse osmosis system from the printing and dyeing industry. It was found that E-O3 only exhibits an efficiency advantage after the removal of carbonate ions. The synergy of ozone and electrolysis lies not only in the generation of hydroxyl radicals, but also in the degradation of organic compounds. Moreover, the combination of electrolysis and ozonation has an inhibitory effect on the decrease in pH, which plays an important role in the synergistic generation of hydroxyl radicals. This pilot-scale study holds reference significance for the engineering applications of the E-O3 technology. [ABSTRACT FROM AUTHOR]