Low pressure-alternating current glow discharge ion source for mass spectrometry.

Authors :
Shi, Lulu
Habib, Ahsan
Bi, Lei
Wen, Luhong
Source :
International Journal of Mass Spectrometry. Dec2024, Vol. 506, pN.PAG-N.PAG. 1p.
Publication Year :
2024

Abstract

For social security and safety, the sensitive explosives detection is crucial. Mass spectrometry (MS), a unique technique that may immediately reveal information about molecular structure, is considered as the "gold standard" in analytical science. Both science and technology now frequently employ MS-based techniques. This study developed an air-based low-pressure alternating current glow discharge (LP-acGD) ion source for MS to investigate its ionization efficiency in both positive and negative ion modes. The LP-acGD ion source gave O 3 −•, CO 3 −•, HCO 3 −, HCO 4 −, NO 2 − and NO 3 − ions that appeared at m/z 48, 60, 61, 77, 46 and 62, respectively in negative ion mode, some of these contributed to the formation of adduct ions. In positive ion mode, only protonated acetone, [Acetone + H]+ m/z 59, was detected at the beginning of the total ion current when 15 and 5 V were applied at orifices 1 and 2, respectively. However, the background ion signals were stabilized by protonated acetone and water cluster ions [(H 2 O) n + H]+ (n = 3, 4) as applied voltages were 40 and 0 V at orifices 1 and 2, respectively. Hydrogen peroxide, 3,4-dinitrotoluene, nitric acid, hexafluorobenzene, triacetone triperoxide and basil leaf were taken as model samples to investigate the efficiency of the ion source. In negative ion mode, H 2 O 2 and HNO 3 gave [H 2 O 2 +O 2 ]- m/z 66 and [HNO 3 +NO 3 ]- m/z 125, whereas 3,4-DNT and HFB exhibited mostly molecular ions. In positive ion mode, TATP yielded fragment ions of [C 3 H 6 O 2 +H]+ m/z 75 and [C 3 H 6 O 3 +H]+ m/z 91. The present method has been validated for detection and quantification of H 2 O 2 and HNO 3. Ion formation mechanisms are also discussed. Low pressure alternating current-glow discharge (LP-acGD) ion source for mass spectrometry. [Display omitted] • Fabrication of low pressure-acglow discharge ion source. • Charging effect plays vital role in formation of ions. • Air functions as carrier gas. • The ion source can be coupled with MS systems for analysis in real samples. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
13873806
Volume :
506
Database :
Academic Search Index
Journal :
International Journal of Mass Spectrometry
Publication Type :
Academic Journal
Accession number :
180630457
Full Text :
https://doi.org/10.1016/j.ijms.2024.117343