Back to Search
Start Over
Combined approach of high‐power and very high‐power, short‐duration ablation in superior vena cava isolation.
- Source :
-
Journal of Cardiovascular Electrophysiology . Nov2024, Vol. 35 Issue 11, p2144-2152. 9p. - Publication Year :
- 2024
-
Abstract
- Introduction: The effectiveness and safety of 50 W, high‐power, short‐duration (HPSD) ablation in superior vena cava isolation (SVCI) for patients with atrial fibrillation (AF) have been reported. However, the acute outcomes of SVCI combined with 90 W/4 s, very high‐power, short‐duration (vHPSD) ablation remain unknown. In this study, we aimed to investigate a novel approach that combines 50 W‐HPSD and 90 W/4 s‐vHPSD ablation in SVCI and to elucidate the characteristics, outcomes, and safety of this approach by comparing SVCI with conventional ablation index (AI)‐guided middle‐power, middle‐duration (MPMD) ablation. Methods: Overall, 126 patients who underwent AF ablation with SVCI using the QDOT MICROTM catheter were retrospectively reviewed; one group underwent SVCI with a combined approach of HPSD and vHPSD ablation (50 W/90 W group, n = 73) and another group underwent AI‐guided MPMD ablation (30–40 W group, n = 53). This study compared the procedural details, radiofrequency (RF) ablation profiles, and complications. The RF settings used in the 50 W/90 W group were 50 W/7 s for the lateral segment close to the phrenic nerve and 90 W/4 s for the nonlateral segment. Results: The 50 W/90 W group required a significantly shorter procedural time (3.2 vs. 5.9 min, p <.001), shorter RF duration (42.0 vs. 162.0 s, p <.001), and lower RF energy (2834 vs. 5480 J, p <.001) than the 30–40 W group. Procedural success, first‐pass SVCI, number of RF applications, and SVC reconnection after isoproterenol loading were comparable between the groups. The maximum tip‐electrode temperature of the multi‐thermocouple system was significantly higher in the 50 W/90 W group than in the 30–40 W group (50.0°C vs. 47.0°C, p <.001). No complications, such as phrenic nerve injury or bleeding requiring transfusion, were observed in either group. Conclusions: The combined approach of 50 W/7 s‐HPSD and 90 W/4 s‐vHPSD ablation resulted in successful and safe SVCI with shorter procedural time, shorter RF duration, and lower RF energy. [ABSTRACT FROM AUTHOR]
- Subjects :
- *PATIENT safety
*ACTION potentials
*VENA cava superior
*SCIENTIFIC observation
*TREATMENT duration
*TREATMENT effectiveness
*DESCRIPTIVE statistics
*RETROSPECTIVE studies
*RADIO frequency therapy
*SURGICAL complications
*ATRIAL fibrillation
*MEDICAL records
*ACQUISITION of data
*PHRENIC nerve
*CATHETER ablation
*COMPARATIVE studies
*HEMORRHAGE
Subjects
Details
- Language :
- English
- ISSN :
- 10453873
- Volume :
- 35
- Issue :
- 11
- Database :
- Academic Search Index
- Journal :
- Journal of Cardiovascular Electrophysiology
- Publication Type :
- Academic Journal
- Accession number :
- 180703334
- Full Text :
- https://doi.org/10.1111/jce.16424