Back to Search Start Over

Cross-talk of a multi-anode PMT and attainment of a TOF counter

Authors :
Enari, Y.
Hayasaka, K.
Hokuue, T.
Inami, K.
Ohshima, T.
Sato, N.
Akatsu, M.
Kawakami, S.
Miyabayashi, Y.
Tokuda, H.
Yanase, H.
Shimoi, H.
Fujimori, T.
Source :
Nuclear Instruments & Methods in Physics Research Section A. Aug2005, Vol. 547 Issue 2/3, p490-503. 14p.
Publication Year :
2005

Abstract

Abstract: We extensively studied a cross-talk phenomenon that seriously deteriorates the high time-resolution of a multi-anode 16-channel linear array photo-multiplier tube (PMT); the dynode structures were modified to eliminate the cross-talk effect and to recover a time resolution of for single photons. The use of 16 anode signals of the modified PMT enabled us to attain for a small TOF counter of Cherenkov radiation. [Copyright &y& Elsevier]