Back to Search
Start Over
Study of Thermo‐Oxidative Aging of Fluorinated Gaskets (FKM) Used in Plate Heat Exchangers.
- Source :
-
Macromolecular Symposia . Dec2024, Vol. 413 Issue 6, p1-6. 6p. - Publication Year :
- 2024
-
Abstract
- Gaskets are sealing elements used in plate heat exchangers, which are subjected to aggressive conditions during service. In particular, the compression state, together alongside temperatures, can cause a premature deterioration of properties. To monitor and prevent such a situation, this study uses the TTS (time‐temperature superposition) method and Arrhenius to predict the lifetime of FKM gaskets. For this purpose, thermo‐oxidative aging is conducted at different temperatures for up to 6 months, monitoring compression set (CS) and Shore A hardness. The results indicate that the gasket can withstand periods of up to almost 300 days in service for an operating temperature of 140 °C. [ABSTRACT FROM AUTHOR]