Back to Search Start Over

Synchronization of multiple spark-gap switches by a transmission line transformer.

Authors :
Liu, Z.
Yan, K.
Pemen, A. J. M.
Winands, G. J. J.
Van Heesch, E. J. M.
Source :
Review of Scientific Instruments. Nov2005, Vol. 76 Issue 11, p113507. 4p. 7 Graphs.
Publication Year :
2005

Abstract

A transmission line transformer (TLT)-based multiple-switch circuit topology was recently proposed for pulsed-power generation. By means of a TLT, multiple spark-gap switches can be synchronized in a short time (ns). It is attractive to be used to design a long-lifetime repetitive large pulsed-power source (100 kW, 1 kHz) for various kinds of applications, such as corona plasma-induced gas cleaning. To gain insight into the synchronization principle and switching behavior of the individual switch, an equivalent circuit model was developed and an experimental setup with two spark-gap switches and a two-stage TLT has been constructed. We observed that in terms of switching currents, the two switches can be synchronized within 2–3 ns. The equivalent circuit model approximately fits the experimental results. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00346748
Volume :
76
Issue :
11
Database :
Academic Search Index
Journal :
Review of Scientific Instruments
Publication Type :
Academic Journal
Accession number :
19215118
Full Text :
https://doi.org/10.1063/1.2132269