First performance evaluation of a dual-source CT (DSCT) system.
- Source :
-
European Radiology . Feb2006, Vol. 16 Issue 2, p256-268. 13p. 1 Color Photograph, 1 Black and White Photograph, 8 Diagrams, 5 Graphs. - Publication Year :
- 2006
-
Abstract
- We present a performance evaluation of a recently introduced dual-source computed tomography (DSCT) system equipped with two X-ray tubes and two corresponding detectors, mounted onto the rotating gantry with an angular offset of 90 degrees . We introduce the system concept and derive its consequences and potential benefits for electrocardiograph [corrected] (ECG)-controlled cardiac CT and for general radiology applications. We evaluate both temporal and spatial resolution by means of phantom scans. We present first patient scans to illustrate the performance of DSCT for ECG-gated cardiac imaging, and we demonstrate first results using a dual-energy acquisition mode. Using ECG-gated single-segment reconstruction, the DSCT system provides 83 ms temporal resolution independent of the patient's heart rate for coronary CT angiography (CTA) and evaluation of basic functional parameters. With dual-segment reconstruction, the mean temporal resolution is 60 ms (minimum temporal resolution 42 ms) for advanced functional evaluation. The z-flying focal spot technique implemented in the evaluated DSCT system allows 0.4 mm cylinders to be resolved at all heart rates. First clinical experience shows a considerably increased robustness for the imaging of patients with high heart rates. As a potential application of the dual-energy acquisition mode, the automatic separation of bones and iodine-filled vessels is demonstrated. [ABSTRACT FROM AUTHOR]
- Subjects :
- *TOMOGRAPHY
*ELECTROCARDIOGRAPHY
*CARDIAC imaging
*HEART beat
*MEDICAL radiography
*MEDICAL equipment
*CORONARY artery stenosis
*ECHOCARDIOGRAPHY
*DIGITAL image processing
*DIAGNOSTIC imaging equipment
*CORONARY angiography
*SPIRAL computed tomography
*COMPARATIVE studies
*DIASTOLE (Cardiac cycle)
*CARDIAC contraction
*RESEARCH methodology
*MEDICAL cooperation
*IMAGING phantoms
*QUALITY assurance
*RESEARCH
*PRODUCT design
*EVALUATION research
*EQUIPMENT & supplies
*DIAGNOSIS
Subjects
Details
- Language :
- English
- ISSN :
- 09387994
- Volume :
- 16
- Issue :
- 2
- Database :
- Academic Search Index
- Journal :
- European Radiology
- Publication Type :
- Academic Journal
- Accession number :
- 19449358
- Full Text :
- https://doi.org/10.1007/s00330-005-2919-2