Back to Search Start Over

Comparison of exposure assessment methods in occupational exposure to benzene in gasoline filling-station attendants

Authors :
Carrieri, Mariella
Bonfiglio, Enrico
Scapellato, Maria Luisa
Maccà, Isabella
Tranfo, Giovanna
Faranda, Paolo
Paci, Enrico
Bartolucci, Giovanni Battista
Source :
Toxicology Letters. Apr2006, Vol. 162 Issue 2/3, p146-152. 7p.
Publication Year :
2006

Abstract

Abstract: The aim of this study was to assess gasoline filling-station attendants’ exposure to benzene and to determine which biological exposure index (BEI), trans,trans-muconic acid (t,t-MA) or S-phenylmercapturic acid (S-PMA), shows better correlation with environmental exposure. Exposure to benzene was measured using passive samplers (Radiello) attached to the collar of the overalls of subjects (n =33) just before the work-shift (approximately 8h); analysis was performed by GC-FID. S-PMA and t,t-MA were determined, respectively, by an immunochemiluminescent assay based on specific monoclonal antibodies and by HPLC–UV at 264nm. Both methods of biological monitoring were performed on beginning and end-shift urine samples, and expected t,t-MA and S-PMA values were calculated. Smoking habits and life-style were ascertained by means of a questionnaire. Both environmental and biological monitoring data showed that benzene exposure for gasoline filling-station attendants was low when compared with the respective ACGIH limit values (means—benzene: 0.044mg/m3; t,t-MA: 171μg/g creatinine; S-PMA: 2.7μg/g creatinine). No significant correlation was found between exposure to benzene and t,t-MA or S-PMA excretion data. The use of expected values was also experimented for S-PMA and t,t-MA. This consists of calculating, on the basis of the known half-life of the benzene metabolite, the concentration of that metabolite that a worker should present at the end of the work-shift, the difference between this value and the value actually found is a measure of benzene exposure during work. The use of expected values in biological monitoring did not improve correlations. At these low benzene levels, environmental monitoring seems to be the best method of evaluating individual exposure. However, biological monitoring remains useful, as a mean of assessing group exposure. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
03784274
Volume :
162
Issue :
2/3
Database :
Academic Search Index
Journal :
Toxicology Letters
Publication Type :
Academic Journal
Accession number :
19770028
Full Text :
https://doi.org/10.1016/j.toxlet.2005.09.036