Back to Search Start Over

Simultaneous detection of HCV and HIV-1 by SYBR Green real time multiplex RT-PCR technique in plasma samples

Authors :
Gibellini, Davide
Gardini, Federica
Vitone, Francesca
Schiavone, Pasqua
Furlini, Giuliano
Carla Re, Maria
Source :
Molecular & Cellular Probes. Jun2006, Vol. 20 Issue 3/4, p223-229. 7p.
Publication Year :
2006

Abstract

Abstract: This paper describes the development of a SYBR Green-based multiplex real time RT-PCR for the simultaneous detection of HCV and HIV-1 genomes in plasma samples. Viral genomes were identified in the same sample by their distinctive melting temperature (Tm) which are 81.6 and 86.5°C for HIV-1 gag 142bp amplicon and HCV 5′-NCR region 226bp amplicon, respectively. Analysis of known scalar concentrations of reference plasma indicated that the multiplex procedure detects at least 500copies/ml of both HIV-1 and HCV. In addition, we also assayed HIV-1 and HCV viral load in 30 co-infected patients and in 15 blood donors, confirming the sensitivity and specificity of the assay. This method may represent a useful alternative method for the detection of HIV-1/HCV co-infection, reliable for a rapid and relatively inexpensive screening of blood donors. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
08908508
Volume :
20
Issue :
3/4
Database :
Academic Search Index
Journal :
Molecular & Cellular Probes
Publication Type :
Academic Journal
Accession number :
20768270
Full Text :
https://doi.org/10.1016/j.mcp.2005.12.005