Control performance of single-phase STATCOM and BTB by three-level inverters.
- Source :
-
Electrical Engineering in Japan . Oct2006, Vol. 157 Issue 1, p54-62. 9p. 2 Black and White Photographs, 3 Diagrams, 3 Charts, 12 Graphs. - Publication Year :
- 2006
-
Abstract
- The so-called three-level inverters have been widely used for industry applications because of high-voltage output ability and low harmonic contents. These applications are mainly suitable for AC motor drives. Recent attention has been paid to larger-capacity inverters applicable to power system control. This paper describes their applications to power systems. First, harmonic analysis of a three-level inverter is achieved under the condition that its two DC capacitor voltage are unbalanced. Second, a control method for balancing the two DC capacitor voltages is described. Finally, applications of single-phase three-level inverters to STATCOM and BTB are introduced. Their control performance is confirmed by computer simulation. © 2006 Wiley Periodicals, Inc. Electr Eng Jpn, 157(1): 54–62, 2006; Published online in Wiley InterScience (<URL>http://www.interscience.wiley.com</URL>). DOI 10.1002/eej.20306 [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 04247760
- Volume :
- 157
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- Electrical Engineering in Japan
- Publication Type :
- Academic Journal
- Accession number :
- 21611116
- Full Text :
- https://doi.org/10.1002/eej.20306