Back to Search
Start Over
Detection of hepatic VX2 carcinomas with ferucarbotran-enhanced magnetic resonance imaging in rabbits: Comparison of nine pulse sequences
- Source :
-
European Journal of Radiology . Sep2006, Vol. 59 Issue 3, p413-423. 11p. - Publication Year :
- 2006
-
Abstract
- Abstract: Objective: To compare the diagnostic performance of a variety of magnetic resonance imaging (MRI) sequences, in order to identify the most effective ferucarbotran-enhanced sequence for the detection of multiple small hepatic VX2 carcinomas in rabbits. Methods: Fifteen rabbits with experimentally induced 135 VX2 carcinomas in the liver underwent ferucarbotran-enhanced MRI using the following nine pulse sequences: a fat-suppressed fast spin-echo (FSE) sequence with two echo times (TE) (proton density- and T2-weighted images), four different T2*-weighted fast multiplanar GRASS (gradient-recalled acquisition in the steady state) (FMPGR) with the combination of three TEs (9, 12, 15ms, respectively) and two flip angles (20°, 80°, respectively), T2*-weighted fast multiplanar spoiled GRASS (FMPSPGR), T1-weighted FMPSPGR, and dynamic T1-weighted FMPSPGR. All images were reviewed by three radiologists with quantitative and qualitative analysis. Results: Tumor-to-liver contrast-to-noise ratio of the proton density-weighted FSE sequence was significantly higher than those of the others (p <0.05). The lesion conspicuities of proton density- and T2-weighted FSE and T2*-weighted FMPGR (TE/flip angle, 9/20° and 12/20°) images were better and the image artifacts of T2*-weighted FMPGR (TE/flip angle, 15/20° and 12/80°) and T2*-weighted FMPSPGR images were more prominent than those of the others (p <0.05). The lesion detection in T2- and proton density-weighted FSE and T2*-weighted FMPGR (TE/flip angle, 12/20°) images were superior to those of the others and for the detection of very small hepatic tumors of less than 5mm, the sensitivities of these sequences were less than 30%. Conclusion: Ferucarbotran-enhanced T2- and proton density-weighted FSE and T2*-weighed FMPGR (TE/flip angle, 12/20°) images were found to be the most effective pulse sequences for the detection of multiple small hepatic VX2 carcinomas but these sequences were limited in the detection of very small hepatic tumors of less than 5mm in size. [Copyright &y& Elsevier]
- Subjects :
- *LIVER cancer
*MAGNETIC resonance imaging
*LABORATORY rabbits
*QUALITATIVE research
*ANIMAL experimentation
*COMPARATIVE studies
*DEXTRAN
*DIGITAL image processing
*IRON
*IRON compounds
*LIVER tumors
*RESEARCH methodology
*MEDICAL cooperation
*NONPARAMETRIC statistics
*OXIDES
*RABBITS
*RESEARCH
*PILOT projects
*EVALUATION research
*CONTRAST media
*RECEIVER operating characteristic curves
*MEDICAL artifacts
Subjects
Details
- Language :
- English
- ISSN :
- 0720048X
- Volume :
- 59
- Issue :
- 3
- Database :
- Academic Search Index
- Journal :
- European Journal of Radiology
- Publication Type :
- Academic Journal
- Accession number :
- 22219625
- Full Text :
- https://doi.org/10.1016/j.ejrad.2006.03.016