Preparing the BESSY APPLE Undulators for Top-Up Operation.

Authors :
Bahrdt, J.
Frentrup, W.
Gaupp, A.
Scheer, M.
Source :
AIP Conference Proceedings. 2007, Vol. 879 Issue 1, p315-318. 4p. 1 Chart, 4 Graphs.
Publication Year :
2007

Abstract

BESSY plans to go to topping up operation in the near future. A high injection efficiency is essential to avoid particle losses inside the undulator magnets and to ensure a low radiation background in the beamlines. Dynamic and static multipoles of the insertion devices have to be minimized to accomplish this requirement. APPLE II devices show strong dynamic multipoles in the elliptical and vertical polarization mode. Measurements before and after shimming of these multipoles are presented. The static multipoles of the BESSY UE56-2 which are due to systematic block inhomgeneities have successfully been shimmed recovering the full dynamic aperture. © 2007 American Institute of Physics [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
879
Issue :
1
Database :
Academic Search Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
23923971
Full Text :
https://doi.org/10.1063/1.2436063