Back to Search Start Over

Integration of trench-isolated through-wafer interconnects with 2d capacitive micromachined ultrasonic transducer arrays

Authors :
Zhuang, Xuefeng
Ergun, Arif S.
Huang, Yongli
Wygant, Ira O.
Oralkan, Omer
Khuri-Yakub, Butrus T.
Source :
Sensors & Actuators A: Physical. Jul2007, Vol. 138 Issue 1, p221-229. 9p.
Publication Year :
2007

Abstract

Abstract: This paper presents a method to provide electrical connection to a 2D capacitive micromachined ultrasonic transducer (CMUT) array. The interconnects are processed after the CMUTs are fabricated on the front side of a silicon wafer. Connections to array elements are made from the back side of the substrate via highly conductive silicon pillars that result from a deep reactive ion etching (DRIE) process. Flip-chip bonding is used to integrate the CMUT array with an integrated circuit (IC) that comprises the front-end circuits for the transducer and provides mechanical support for the trench-isolated array elements. Design, fabrication process and characterization results are presented. The advantages when compared to other through-wafer interconnect techniques are discussed. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
09244247
Volume :
138
Issue :
1
Database :
Academic Search Index
Journal :
Sensors & Actuators A: Physical
Publication Type :
Academic Journal
Accession number :
25618810
Full Text :
https://doi.org/10.1016/j.sna.2007.04.008