A New Critical Formula and Mathematical Model of Double-Tap Interphase Reactor in a Six-Phase Tap-Changer Diode Rectifier.

Authors :
Pan Qijun
Ma Weiming
Liu Dezhi
Zhao Zhihua
Meng Jin
Source :
IEEE Transactions on Industrial Electronics. Feb2007, Vol. 54 Issue 1, p479-485. 7p. 4 Diagrams, 6 Graphs.
Publication Year :
2007

Abstract

This paper presents a new practical formula to calculate the critical value of interphase reactor (IPR) in a six-phase diode rectifier with tap-changer. In addition, a mathematical model of the double-tap IPR has been established by equivalent circuit method. Simulation and experimental results verify the validity of the formula and mathematical model. On the basis of the above achievements, a simple and effective approach is provided to design the IPR and to analyze the performance of the whole system. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02780046
Volume :
54
Issue :
1
Database :
Academic Search Index
Journal :
IEEE Transactions on Industrial Electronics
Publication Type :
Academic Journal
Accession number :
26095726
Full Text :
https://doi.org/10.1109/TIE.2006.888800