Back to Search Start Over

Solving fecal coliform growth/reactivation in biosolids during full-scale post-digestion processes.

Authors :
Iranpour, R.
Palacios, R.
Cox, H. H. J.
Abkian, V.
Source :
Water Science & Technology. 2005, Vol. 52 Issue 1/2, p283-288. 6p.
Publication Year :
2005

Abstract

Fecal coliform recurrence has been observed at the City of Los Angeles Hyperion Treatment Plant during pilot-scale experiments with a designated thermophilic battery of six anaerobic digesters, while other digesters were still at a mesophilic temperature. Several lab and full-scale experiments indicated the following possible causes of the growth/reactivation of fecal coliforms in post-digestion: a) contamination of thermophilically digested biosolids with mesophilically digested biosolids; b) a large drop in the biosolids temperature between the centrifuges and silos, which could have allowed the reactivation and/or growth of fecal coliforms. These were resolved by the full plant conversion to thermophilic anaerobic digestion and design modifications of the post-digestion train. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02731223
Volume :
52
Issue :
1/2
Database :
Academic Search Index
Journal :
Water Science & Technology
Publication Type :
Academic Journal
Accession number :
26551000
Full Text :
https://doi.org/10.2166/wst.2005.0529