Back to Search Start Over

A Simple Technique for Determining Slug Frequency Using Differential Pressure.

Authors :
Wilkens, R. J.
Thomas, D. K.
Source :
Journal of Energy Resources Technology. Mar2008, Vol. 130 Issue 1, p1-6. 6p. 1 Chart, 5 Graphs.
Publication Year :
2008

Abstract

An experiment was performed to study air/water slug frequency in a horizontal clear pipe by means of visual inspection and differential pressure measurement in the range of 0-1/s. Results showed that a simplified model for slug pressure drop allowed the differential pressure data to compare favorably with visual observations for slug frequency. it was concluded that this technique gives a proper estimation of slug frequency, given only basic flow information. it is recommended that this technique be used when constrained to differential pressure or used to analyze existing differential pressure data. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01950738
Volume :
130
Issue :
1
Database :
Academic Search Index
Journal :
Journal of Energy Resources Technology
Publication Type :
Academic Journal
Accession number :
31197517
Full Text :
https://doi.org/10.1115/1.2824297