Back to Search Start Over

Use of Code Error and Beat Frequency Test Method to Identify Single Event Upset Sensitive Circuits in a 1 GHz Analog to Digital Converter.

Authors :
Kruckmeyer, Kirby
Rennie, Robert L.
Ramachandran, Vishwanath
Source :
IEEE Transactions on Nuclear Science. Aug2008 Part 1 of 2, Vol. 55 Issue 4, p2013-2018. 6p. 4 Diagrams, 1 Chart, 4 Graphs.
Publication Year :
2008

Abstract

Typical test methods for characterizing the single event upset performance of an analog to digital converter (ADC) have involved holding the input at static values. As a result, output error signatures are seen for only a few input voltage and output codes. A test method using an input beat frequency and output code error detection allows an ADC to be characterized with a dynamic input at a high frequency. With this method, the impact of an ion strike can be seen over the full code range of the output. The error signatures from this testing can provide clues to which area of the ADC is sensitive to an ion strike. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00189499
Volume :
55
Issue :
4
Database :
Academic Search Index
Journal :
IEEE Transactions on Nuclear Science
Publication Type :
Academic Journal
Accession number :
34956839
Full Text :
https://doi.org/10.1109/TNS.2008.921940