Back to Search Start Over

Magnetic beads-based immunoassay as a sensitive alternative for atrazine analysis

Authors :
Tudorache, Madalina
Tencaliec, Anca
Bala, Camelia
Source :
Talanta. Dec2008, Vol. 77 Issue 2, p839-843. 5p.
Publication Year :
2008

Abstract

Abstract: A new immunoassay strategy for sensitive atrazine determination based on magnetic beads is reported. The immuno-method is a competitive solid-phase immunoassay where the anti-atrazine antibody is immobilized on the magnetic beads surface and fixed at the reaction cell bottom using a simple magnet, which generates a magnetic field. Analyte and HRP (horseradish peroxidase) tracer compete for active sites of antibody. After the immunointeractions antibody-analyte and antibody-tracer, atrazine quantification from the sample is performed by injection of the chemiluminescence substrate (luminol, hydrogen peroxide and p-iodophenol). Different antibodies (polyIgG anti-atrazine Ab I and affinity purified polyIgG anti-atrazine AbI) were tested in this configuration. Also, optimum concentration of antibody-covered magnetic beads was set up (8mg/l Ab II). Finally, the performance of magnetic beads-based immunoassay for atrazine determination was evaluated demonstrating that the magnetic beads-based immunoassay is one of the most sensitive method for atrazine determination (LoD=3pg/l, IC50 =37pg/l, DR=10–1000pg/l). [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
00399140
Volume :
77
Issue :
2
Database :
Academic Search Index
Journal :
Talanta
Publication Type :
Academic Journal
Accession number :
34979286
Full Text :
https://doi.org/10.1016/j.talanta.2008.07.040