Back to Search Start Over

A Novel Method to Diagnose PWM-fed Induction Motors.

Authors :
Cavallini, Andrea
Fabiani, Davide
Montanari, Gian Carlo
Source :
IEEE Transactions on Dielectrics & Electrical Insulation. Oct2008, Vol. 15 Issue 5, p1313-1321. 9p. 3 Black and White Photographs, 2 Diagrams, 2 Charts, 12 Graphs.
Publication Year :
2008

Abstract

A novel method for measurement and interpretation of PD phenomena in inverter-fed motors is discussed in this paper. The interpretation of PD measurements is carried out resorting to the direct-quadrature (dq) transform of the three voltages at motor terminals at the instant a PD event occurs. New tools (the dq loci, dq Hq and dq Hn patterns) are proposed to infer PD activity in a statistical way, similar to that used under AC supply. The method has been validated through tests on motorettes. In addition, measurements on low-voltage inverter-fed motors subjected to repetitive surges till breakdown are reported to support the capability of the method to infer onsetting faults. Measurements are performed through a reliable and lightweight (thus suitable for, e.g., automotive or avionics applications) antenna coupler characterized by excellent signal-to-nose ratio. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10709878
Volume :
15
Issue :
5
Database :
Academic Search Index
Journal :
IEEE Transactions on Dielectrics & Electrical Insulation
Publication Type :
Academic Journal
Accession number :
35008863
Full Text :
https://doi.org/10.1109/TDEI.2008.4656239