Back to Search Start Over

Electrostatic Discharge and Secondary Arcing on Solar Array—Flashover Effect on Arc Occurrence.

Authors :
Inguimbert, Virginie
Sarrail, Daniel
Mateo-Velez, Jean-Charles
Reulet, René
Levy, Leon
Boulay, Françoise
Payan, Denis
Source :
IEEE Transactions on Plasma Science. Oct2008 Part 2 of 4, Vol. 36 Issue 5, p2404-2412. 9p. 4 Black and White Photographs, 3 Diagrams, 2 Charts, 14 Graphs.
Publication Year :
2008

Abstract

A good representativeness of the test setup used for the qualification of solar arrays is fundamental. We know now that the fiashover current involved in the electrostatic discharge is related with the total dielectric surface neutralized during the electrostatic discharge. This paper presents experiments on samples of different sizes, performed in a large vacuum chamber, JONAS, installed in ONERA/DESP, Toulouse, France. The samples are tested in the inverted voltage gradient configuration obtained with electrons. We observed that secondary arcs obtained on a large sample (i.e., with a long fiashover) had much longer durations than those on a small sample, i.e., the flashover is a critical parameter for secondary arc initiation and sustainment. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00933813
Volume :
36
Issue :
5
Database :
Academic Search Index
Journal :
IEEE Transactions on Plasma Science
Publication Type :
Academic Journal
Accession number :
35735589
Full Text :
https://doi.org/10.1109/TPS.2008.2001836