Back to Search Start Over

A Discontinuous PWM Method for Balancing the Neutral Point Voltage in Three-Level Inverter-Fed Variable Frequency Drives.

Authors :
Ben-Brahim, Lazhar
Source :
IEEE Transactions on Energy Conversion. Dec2008, Vol. 23 Issue 4, p1057-1063. 7p. 1 Black and White Photograph, 15 Diagrams, 1 Chart, 1 Graph.
Publication Year :
2008

Abstract

The paper describes a new discontinuous carrier-based pulsewidth modulation (PWM) method for use in variable frequency drives (VFD) driven by three-level inverters. The method introduces three different switching patterns for the full range of operating speeds. Depending on the actual operating speed, the proposed algorithm is developed to select the most suitable PWM switching pattern that improves the VFD performance. This results in low imbalance in the dc-link capacitor voltage, and low current distortions without increasing switching losses. Theory, simulation, and experimental results are presented. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08858969
Volume :
23
Issue :
4
Database :
Academic Search Index
Journal :
IEEE Transactions on Energy Conversion
Publication Type :
Academic Journal
Accession number :
35775779
Full Text :
https://doi.org/10.1109/TEC.2008.2001435