Back to Search Start Over

Prior Human Leukocyte Antigen-Allosensitization and Left Ventricular Assist Device Type Affect Degree of Post-implantation Human Leukocyte Antigen-Allosensitization

Authors :
Drakos, Stavros G.
Kfoury, Abdallah G.
Kotter, John R.
Reid, Bruce B.
Clayson, Stephen E.
Selzman, Craig H.
Stehlik, Josef
Fisher, Patrick W.
Merida, Mario
Eckels, David D.
Brunisholz, Kim
Horne, Benjamin D.
Stoker, Sandi
Li, Dean Y.
Renlund, Dale G.
Source :
Journal of Heart & Lung Transplantation. Aug2009, Vol. 28 Issue 8, p838-842. 5p.
Publication Year :
2009

Abstract

Left ventricular assist device (LVAD) implantation before heart transplantation has been associated with formation of antibodies directed against human leukocyte antigens (HLA), often referred to as sensitization. This study investigated whether prior sensitization or LVAD type affected the degree of post-implantation sensitization. The records of consecutive HeartMate (HM) I and HM II LVAD patients were reviewed. Panel reactive antibody (PRA) was assessed before LVAD implantation and biweekly thereafter. Sensitization was defined as PRA > 10%, and high-degree sensitization was defined as PRA > 90%. An HM LVAD was implanted in 64 patients, and 11 received a HM II LVAD as a bridge to transplant. Ten HM I patients (16%) were sensitized before LVAD implantation (HM I-S), and 54 (84%) were not (HM I-Non-S). Nine HM I-S patients (90%) became highly sensitized (PRA > 90%) compared with 9 HM I-Non-S patients (16.7%; p < 0.001). The PRA remained elevated (> 90%) in 8 of the 9 (88.9%) highly sensitized HM I-S patients vs 5 of the 9 (55.6%) HM I-Non-S highly sensitized patients. The PRA levels in the rest of the HM I-S highly sensitized patients declined from 93% ± 4% to 55% ± 15% (p = 0.01). Among the 11 HM II patients, 1 (9%) was sensitized before LVAD implantation (PRA, 40%) and the PRA moderately increased to 80%. No other HM II patient became sensitized after implantation. Thus, 1 of 11 (9%) HM II patients became sensitized compared with 29 of 64 (45%) HM I patients (p = 0.04). Pre-sensitized patients are at higher risk for becoming and remaining highly HLA-allosensitized after LVAD implantation. The HeartMate II LVAD appears to cause less sensitization than HeartMate I. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
10532498
Volume :
28
Issue :
8
Database :
Academic Search Index
Journal :
Journal of Heart & Lung Transplantation
Publication Type :
Academic Journal
Accession number :
43409929
Full Text :
https://doi.org/10.1016/j.healun.2009.04.031