Back to Search Start Over

Use of biocidal products (insect sprays and electro-vaporizer) in indoor areas – Exposure scenarios and exposure modeling

Authors :
Berger-Preiß, Edith
Koch, Wolfgang
Gerling, Susanne
Kock, Heiko
Appel, Klaus E.
Source :
International Journal of Hygiene & Environmental Health. Sep2009, Vol. 212 Issue 5, p505-518. 14p.
Publication Year :
2009

Abstract

Abstract: Five commercially available insect sprays were applied in a model room. Spraying was performed in accordance with the manufacturers’ instructions and in an overdosed manner in order to simulate worst-case conditions or an unforeseeable misuse. In addition, we examined electro-vaporizers. The Respicon™ aerosol monitoring system was applied to determine inhalation exposure. During normal spraying (10 seconds) and during the following 2–3 minutes, exposure concentrations ranged from 70 to 590μg/m3 for the pyrethroids tetramethrin, d-phenothrin, cyfluthrin, bioallethrin, and the pyrethrins. Calculated inhalable doses were 2–16μg. A concentration of approximately 850μg chlorpyrifos/m3 (inhalable dose: approximately 20μg) was determined when the “Contra insect fly spray” was applied. Highest exposure concentrations (1100–2100μg/m3) were measured for piperonyl butoxide (PBO), corresponding to an inhalation intake of 30–60μg. When simulating worst-case conditions, exposure concentrations of 200–3400μg/m3 and inhalable doses of 10–210μg were determined for the various active substances. Highest concentrations (4800–8000μg/m3) were measured for PBO (inhalable: 290–480μg). By applying the electro-vaporizer “Nexa Lotte” plug-in mosquito killer concentrations for d-allethrin were in the range of 5–12μg/m3 and 0.5–2μg/m3 for PBO while with the “Paral” plug-in mosquito killer concentrations of 0.4–5μg/m3 for pyrethrins and 1–7μg/m3 for PBO were measured. Potential dermal exposures were determined using exposure pads. Between 80 and 1000μg active substance (tetramethrin, phenothrin, cyfluthrin, bioallethrin, pyrethrins, chlorpyrifos) were deposited on the clothing of the total body surface area of the spray user. Highest levels (up to 3000μg) were determined for PBO. Worst-case uses of the sprays led to 5–9 times higher concentrations. Also a 2-hour stay nearby an operating electro-vaporizer led to a contamination of the clothing (total amounts on the whole body were 450μg d-allethrin and 50μg PBO for “Nexa Lotte” plug-in mosquito killer and 80μg pyrethrins and 190μg PBO for “Paral” plug-in mosquito killer). Human biomonitoring data revealed urine concentrations of the metabolite (E)-trans-chrysanthemum dicarboxylic acid ((E)-trans-CDCA) between 1.7μg/l and 7.1μg/l after 5 minutes of exposure to the different sprays. Also the use of electro-vaporizers led to (E)-trans-CDCA concentrations in the urine in the range of 1.0μg/l to 6.2μg/l (1–3 hours exposure period). The exposure data presented can be used for performing human risk assessment when these biocidal products were applied indoors. The airborne concentrations of the non-volatile active chemical compounds could be predicted from first principles using a deterministic exposure model (SprayExpo). [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
14384639
Volume :
212
Issue :
5
Database :
Academic Search Index
Journal :
International Journal of Hygiene & Environmental Health
Publication Type :
Academic Journal
Accession number :
43414633
Full Text :
https://doi.org/10.1016/j.ijheh.2009.02.001