Back to Search Start Over

Chlorine and sulfur determination in extra-heavy crude oil by inductively coupled plasma optical emission spectrometry after microwave-induced combustion

Authors :
Pereira, Juliana S.F.
Mello, Paola A.
Moraes, Diogo P.
Duarte, Fábio A.
Dressler, Valderi L.
Knapp, Guenter
Flores, Érico M.M.
Source :
Spectrochimica Acta Part B. Jun2009, Vol. 64 Issue 6, p554-558. 5p.
Publication Year :
2009

Abstract

Abstract: In this study, microwave-induced combustion (MIC) of extra-heavy crude oil is proposed for further chlorine and sulfur determination by inductively coupled plasma optical emission spectrometry (ICP OES). Combustion was carried out under oxygen pressure (20 bar) in quartz vessels using ammonium nitrate (50 µl of 6 mol l−1 solution) as ignition aid. Samples were wrapped with polyethylene film and placed on a quartz holder positioned inside the quartz vessels. The need for an additional reflux step after combustion and the type and concentration of absorbing solution (water, 0.02 to 0.9 mmol l−1 H2O2, 10 to 100 mmol l−1 (NH4)2CO3 or 0.1 to 14 mol l−1 HNO3) were studied. The influence of sample mass, O2 pressure and maximum pressure attained during the combustion process were investigated. Recoveries from 92 to 102% were obtained for Cl and S for all absorbing solutions. For comparison, Cl and S determination was also performed by ion chromatography (IC) using 25 mmol l−1 (NH4)2CO3 as absorbing solution. Using MIC with a reflux step the agreement was better than 95% for certified reference materials of similar composition (crude oil, petroleum coke, coal and residual fuel oil). Microwave-assisted digestion and water extraction in high pressure closed vessels were also evaluated. Using these procedures the maximum recoveries were 30 and 98% for Cl and S, respectively, using microwave-assisted digestion and 70% for Cl and less than 1% for S by water extraction procedure. Limits of detection by ICP OES were 12 and 5 µg g−1 for Cl and S, respectively, and the corresponding values by IC were 1.2 and 8 µg g−1. Using MIC it was possible to digest simultaneously up to eight samples resulting in a solution suitable for the determination of both analytes with a single combustion step. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
05848547
Volume :
64
Issue :
6
Database :
Academic Search Index
Journal :
Spectrochimica Acta Part B
Publication Type :
Academic Journal
Accession number :
43561205
Full Text :
https://doi.org/10.1016/j.sab.2009.01.011