Back to Search Start Over

KSTAR Magnetic Field Measurement During the Commissioning and Remanent Field Evaluation.

Authors :
Yonekawa, Hirofumi
Kim, Y. O.
Hyun Jung Lee
Yoon, S. W.
Hahn, S. H.
Lee, K. S.
Lee, D. K.
Soo Hwan Park
Yong Chu
Bang, E. N.
Park, K. R.
Oh, Y. K.
Bak, J. S.
Leuer, J. A.
Source :
IEEE Transactions on Applied Superconductivity. Jun2009 Part 2 of 3, Vol. 19 Issue 3, p1573-1576. 4p. 2 Black and White Photographs, 2 Charts, 5 Graphs.
Publication Year :
2009

Abstract

An in-situ measurement of the magnetic field generated by the assembled superconducting magnet coils was held by using precision Hall sensors during the commissioning of the Korea Superconducting Tokamak Advanced Research (KSTAR) device. This was done in order to investigate the magnetic influence of Incoloy 908, which is the jacket material for the cable-in-conduit conductors (CICCs) of the Nb3 Sn coils. After the PF coils were discharged from 1 kA the vertical remanent field at the plasma center was more than 10 G, while the TF coils were not energized. The vertical magnetic field generated by the PF coils had a discrepancy of up to 50 G between measurement and the calculation assuming no magnetic influence of Incoloy 908. Thus, non-negligible ferromagnetism was identified and attributed to Incoloy 908. In contrast, most of the hysteresis observed in the magnetic measurements was eliminated when the Incoloy 908 of the TF windings was saturated by the TF coil charging. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10518223
Volume :
19
Issue :
3
Database :
Academic Search Index
Journal :
IEEE Transactions on Applied Superconductivity
Publication Type :
Academic Journal
Accession number :
43923784
Full Text :
https://doi.org/10.1109/TASC.2009.2018486