Back to Search Start Over

Energy Efficiency Analysis of the Discharge Circuit of Caltech Spheromak Experiment.

Authors :
Kumar, Deepak
Moser, Auna L.
Bellan, Paul M.
Source :
IEEE Transactions on Plasma Science. Jan2010, Vol. 38 Issue 1, p47-52. 6p. 4 Black and White Photographs, 3 Diagrams, 2 Charts, 6 Graphs.
Publication Year :
2010

Abstract

The Caltech spheromak experiment uses a size A ignitron in switching a 59-μF capacitor bank (charged up to 8 kV) across an inductive plasma load. Typical power levels in the discharge circuit are ∼200 MW for a duration of ∼10 μs. This paper describes the setup of the circuit and the measurements of various impedances in the circuit. The combined impedance of the size A ignitron and the cables was found to be significantly larger than the plasma impedance. This causes the circuit to behave like a current source with low energy transfer efficiency. This behavior is expected to be common with other pulsed plasma experiments of similar size that employ an ignitron switch. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00933813
Volume :
38
Issue :
1
Database :
Academic Search Index
Journal :
IEEE Transactions on Plasma Science
Publication Type :
Academic Journal
Accession number :
48262712
Full Text :
https://doi.org/10.1109/TPS.2009.2034744