- Abstract: Occluded gaseous cavities within the insulating materials are potential sources of electrical trees which can lead to continuous deterioration and breakdown of materials. To determine the suitability of use and to acquire the data for the dimensioning of electrical insulation systems breakdown voltage of insulators should be determined. In this paper, fuzzy logic (FL) method is used to model breakdown voltages of White Minilex Paper samples based on experimental data generated in the laboratory. Different models are proposed with different shapes of the membership functions for the FL under both dc and ac voltage conditions. The cavities are created artificially with different dimensions. Low values of mean absolute errors of the estimated breakdown voltage of the test data show the effectiveness of such models. [Copyright &y& Elsevier]