Back to Search Start Over

Numerical Method for the Investigation of Fault Containment and Tank Rupture of Power Transformers.

Authors :
Dastous, Jean-Bernard
Lanteigne, Jacques
Foata, Marc
Source :
IEEE Transactions on Power Delivery. Jul2010, Vol. 25 Issue 3, p1657-1665. 9p.
Publication Year :
2010

Abstract

This paper presents an analysis method based on explicit dynamic analysis, enabling detailed and representative investigations of the mechanical effects of low-impedance faults in power equipment. To illustrate the effectiveness of the proposed method, a given transformer design having caused the projection of a heavy chimney/bushing assembly over a significant distance is used as a case study. A comparison about the observed projection distance of this assembly shows that the method provides representative results, thus offering the significant advantage of replacing costly and unpractical tests. The method is then used to study the retrofit measure proposed in this case to retain the chimney, further exemplifying its power to effectively study different design and retrofitting options. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08858977
Volume :
25
Issue :
3
Database :
Academic Search Index
Journal :
IEEE Transactions on Power Delivery
Publication Type :
Academic Journal
Accession number :
52044740
Full Text :
https://doi.org/10.1109/TPWRD.2010.2047277