Design Considerations for a Low-Voltage High-Current Redundant Parallel Voltage Regulator Module System.

Authors :
Mishra, Santanu
Zhou, Xingsheng
Source :
IEEE Transactions on Industrial Electronics. 04/01/2011, Vol. 58 Issue 4, p1330-1338. 9p.
Publication Year :
2011

Abstract

This paper presents the design considerations for a redundant parallel multiphase voltage regulator module (VRM) system. The VRMs are modulated to achieve a controlled current source property, which helps in achieving good current sharing among modules with true redundancy. The steady-state, small-signal, and large-signal characteristics of the control are discussed. A novel local sense feedback is used to improve the large-signal dynamics of the parallel system. Two 3.3-V/140-A prototypes are used to validate the design concepts. Experimental results show good correlation with the theoretical models. The current sharing between the parallel modules is within 10%, and the dynamic voltage response improvement is 33%, as a result of the local sense feedback. [ABSTRACT FROM AUTHOR]