Variable-Duty-Cycle Control to Achieve High Input Power Factor for DCM Boost PFC Converter.
- Source :
-
IEEE Transactions on Industrial Electronics . 05/01/2011, Vol. 58 Issue 5, p1856-1865. 10p. - Publication Year :
- 2011
-
Abstract
- A discontinuous-current-mode (DCM) boost power factor correction (PFC) converter features zero-current turn-on for the switch, no reverse recovery in diode, and constant–frequency operation. However, the input power factor (PF) is relatively low when the duty cycle is constant in a half line cycle. This paper derives the expressions of the input current and PF of the DCM boost PFC converter, and based on that, variable-duty-cycle control is proposed so as to improve the PF to nearly unity in the whole input–voltage range. A method of fitting the duty cycle is further proposed for simplifying the circuit implementation. Other than a higher PF, the proposed variable-duty-cycle control achieves a lower output–voltage ripple and a higher efficiency over constant-duty-cycle control. The experimental results from a 120-W universal input prototype are presented to verify the effectiveness of the proposed method. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 02780046
- Volume :
- 58
- Issue :
- 5
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Industrial Electronics
- Publication Type :
- Academic Journal
- Accession number :
- 59954298
- Full Text :
- https://doi.org/10.1109/TIE.2010.2052538