Back to Search
Start Over
EMI Analysis and Evaluation of an Improved ZCT Flyback Converter.
- Source :
-
IEEE Transactions on Power Electronics . Aug2011, Vol. 26 Issue 8, p2326-2334. 9p. - Publication Year :
- 2011
-
Abstract
- Switching power supplies are sources of noise for sensitive circuits. Converters should comply with electromagnetic compatibility (EMC) rules so that the electromagnetic interference (EMI) caused by switching cannot interfere with the normal operation of adjacent circuits and also the converter itself. The produced interference can be in the form of conduction or radiation. In this paper, some techniques are used in switching converters to suppress EMI with emphasis on the conduction form. EMI analysis and evaluation of a conventional flyback converter and a proposed zero-current transition (ZCT) flyback converter is achieved by simulation and experimental results. In addition to evaluating some EMI suppression techniques, the main objective of this paper is to improve EMI in the topology design stage. The operating modes of the improved ZCT flyback are discussed. In addition to the efficiency improvement, the amount of EMI reduction of this ZCT flyback and the effectiveness of some EMI reduction techniques are shown by practical implementation. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 08858993
- Volume :
- 26
- Issue :
- 8
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Power Electronics
- Publication Type :
- Academic Journal
- Accession number :
- 64123095
- Full Text :
- https://doi.org/10.1109/TPEL.2010.2095884