Back to Search Start Over

Everolimus-Eluting Versus Sirolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: The EXCELLENT (Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting) Randomized Trial

Authors :
Park, Kyung Woo
Chae, In-Ho
Lim, Do-Sun
Han, Kyoo-Rok
Yang, Han-Mo
Lee, Hae-Young
Kang, Hyun-Jae
Koo, Bon-Kwon
Ahn, Taehoon
Yoon, Jung-Han
Jeong, Myung-Ho
Hong, Taek-Jong
Chung, Woo-Young
Jo, Sang-Ho
Choi, Young-Jin
Hur, Seung-Ho
Kwon, Hyuck-Moon
Jeon, Dong-Woon
Kim, Byung-Ok
Park, Si-Hoon
Source :
Journal of the American College of Cardiology (JACC). Oct2011, Vol. 58 Issue 18, p1844-1854. 11p.
Publication Year :
2011

Abstract

Objectives: The goal of this study was to compare the angiographic outcomes of everolimus-eluting stents (EES) and sirolimus-eluting stents (SES) in a head-to-head manner. Background: EES have been shown to be superior to paclitaxel-eluting stents in inhibiting late loss (LL) and clinical outcome. Whether EES may provide similar angiographic and clinical outcomes compared with SES is undetermined. Methods: This was a prospective, randomized, open-label, multicenter trial to demonstrate the noninferiority of EES compared with SES in preventing LL at 9 months. A total of 1,443 patients undergoing percutaneous coronary intervention were randomized 3:1 to receive EES or SES. Routine follow-up angiography was recommended at 9 months. The primary endpoint was in-segment LL at 9 months, and major secondary endpoints included in-stent LL at 9 months, target lesion failure, cardiac death, nonfatal myocardial infarction, target lesion revascularization, and stent thrombosis at 12 months. Data were managed by an independent management center, and clinical events were adjudicated by an independent adjudication committee. Results: Clinical follow-up was available in 1,428 patients and angiographic follow-up in 924 patients (1,215 lesions). The primary endpoint of the study (in-segment LL at 9 months) was 0.11 ± 0.38 mm and 0.06 ± 0.36 mm for EES and SES, respectively (p for noninferiority = 0.0382). The in-stent LL was also noninferior (EES 0.19 ± 0.35 mm; SES 0.15 ± 0.34 mm; p for noninferiority = 0.0121). The incidence of clinical endpoints was not statistically different between the 2 groups, including target lesion failure (3.75% vs. 3.05%; p = 0.53) and stent thrombosis (0.37% vs. 0.83%; p = 0.38). Conclusions: EES were noninferior to SES in inhibition of LL after stenting, which was corroborated by similar rates of clinical outcomes. (Efficacy of Xience/Promus Versus Cypher in Reducing Late Loss After Stenting [EXCELLENT]; NCT00698607) [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
07351097
Volume :
58
Issue :
18
Database :
Academic Search Index
Journal :
Journal of the American College of Cardiology (JACC)
Publication Type :
Academic Journal
Accession number :
66768351
Full Text :