A Retrofit Capacitive Sensing Occupancy Detector Using Fluorescent Lamps.

Authors :
Cooley, John J.
Avestruz, Al-Thaddeus
Leeb, Steven B.
Source :
IEEE Transactions on Industrial Electronics. Dec2011, Vol. 59 Issue 4, p1898-1911. 14p.
Publication Year :
2011

Abstract

This paper presents a retrofit system that exploits a fluorescent lamp's own stray electric fields for capacitive sensing. Occupancy detection for demand-side energy management is a key application. The experimental system demonstrates a detection range of 10 ft. between the lamp and the nearest edge of the occupant. A full system model is presented including the simulation of a lumped element capacitive model. The full system model is validated against experimental data. [ABSTRACT FROM AUTHOR]