Back to Search
Start Over
High temperature corrosion and microstructure deterioration of KHR35H radiant tubes in continuous annealing furnace
- Source :
-
Engineering Failure Analysis . Apr2012, Vol. 21, p59-66. 8p. - Publication Year :
- 2012
-
Abstract
- Abstract: High temperature corrosion and microstructure deterioration phenomenon of KHR35H radiant tubes had been investigated after a service life of approximately 2years in annealing process. Analyses revealed that deterioration in mechanical properties of the radiant tube was caused primarily by significant growth of precipitates during high temperature service. Internal oxidation and simultaneously in situ carbides dissolution were responsible for the formation of large number of voids and microcracks at the inner wall of the tubes, which brought the reduction of effective thickness of the tube wall and may act as crack sources under either thermal shock or creep deformation. [Copyright &y& Elsevier]
Details
- Language :
- English
- ISSN :
- 13506307
- Volume :
- 21
- Database :
- Academic Search Index
- Journal :
- Engineering Failure Analysis
- Publication Type :
- Academic Journal
- Accession number :
- 71415575
- Full Text :
- https://doi.org/10.1016/j.engfailanal.2011.11.016