Back to Search Start Over

An Active–Reactive Power Method for the Diagnosis of Rotor Faults in Three-Phase Induction Motors Operating Under Time-Varying Load Conditions.

Authors :
Cruz, Sérgio M. A.
Source :
IEEE Transactions on Energy Conversion. Mar2012, Vol. 27 Issue 1, p71-84. 14p.
Publication Year :
2012

Abstract

This paper presents a new method to diagnose rotor faults in operating three-phase induction motors under the presence of time-varying loads. The proposed diagnostic strategy relies on a combined analysis of the amplitude and phase spectra of the instantaneous active and reactive powers of the motor, and allows to discriminate the effects introduced by a rotor fault from the ones caused by an oscillating load torque, even when these phenomena occur simultaneously. A theoretical analysis carried out using a linearized model of the induction motor in a synchronous reference frame, complemented with several simulation and experimental results, confirms the validity of the proposed diagnostic approach. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08858969
Volume :
27
Issue :
1
Database :
Academic Search Index
Journal :
IEEE Transactions on Energy Conversion
Publication Type :
Academic Journal
Accession number :
73614340
Full Text :
https://doi.org/10.1109/TEC.2011.2178027