Back to Search
Start Over
Measurement of low-energy antiproton detection efficiency in BESS below <f>1 GeV</f>
- Source :
-
Nuclear Instruments & Methods in Physics Research Section A . Aug2002, Vol. 489 Issue 1-3, p170. 8p. - Publication Year :
- 2002
-
Abstract
- An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be <f>±5%</f>, compared with the previous estimation of <f>±15%</f> which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. [Copyright &y& Elsevier]
- Subjects :
- *NUCLEAR counters
*ANTIPROTONS
Subjects
Details
- Language :
- English
- ISSN :
- 01689002
- Volume :
- 489
- Issue :
- 1-3
- Database :
- Academic Search Index
- Journal :
- Nuclear Instruments & Methods in Physics Research Section A
- Publication Type :
- Academic Journal
- Accession number :
- 7873824
- Full Text :
- https://doi.org/10.1016/S0168-9002(02)00804-5