Back to Search Start Over

Usefulness of pulse-wave Doppler tissue sampling and dobutamine stress echocardiography for the diagnosis of right coronary artery narrowing.

Authors :
Rambaldi, Riccardo
Poldermans, Don
Fioretti, Paolo M.
Cate, Folkert J. ten
Vletter, Wim B.
Bax, Jeroen J.
Roelandt, Jos R.T.C.
Rambaldi, R
Poldermans, D
Fioretti, P M
ten Cate, F J
Vletter, W B
Bax, J J
Roelandt, J R
Source :
American Journal of Cardiology. 06/15/98, Vol. 81 Issue 12, p1411-1415. 5p. 4 Charts, 7 Graphs.
Publication Year :
1998

Abstract

To study the feasibility and diagnostic accuracy of right coronary artery (RCA) narrowing by right ventricular (RV) pulse-wave Doppler tissue sampling during dobutamine stress echocardiography (DSE), 30 patients (mean age 55 +/- 9.5 years, 26 men) with suspected coronary artery disease underwent DSE (up to 40 microg/kg/min with additional atropine during submaximum heart rate responses). Pulse-wave Doppler tissue sampling of RV free walls close to the tricuspid annulus was performed in the apical 4-chamber view. The maximum velocity during the ejection phase, early, and late diastole was measured. Data from 5 consecutive beats were averaged. The measurements were repeated at rest, at low dose (10 microg/kg/min), and at peak dobutamine stress. The results were evaluated for the prediction of significant proximal or medium RCA narrowing (> or = 50% diameter stenosis, assessed by quantitative coronary angiography within the previous 3 months). A progressive increase of the ejection phase velocity (> 25% between 10 microg/kg/min and peak stress) was predictive of a normal RCA, whereas a blunted increase and/or decrease (< 25% of increase) was predictive of significant RCA narrowing: sensitivity (95% confidence intervals): 82% (68 to 96), specificity: 78% (67 to 93), positive predictive value: 69% (52 to 86), negative predictive value: 88% (75 to 100), accuracy: 79% (65 to 94). Pulse-wave Doppler tissue sampling provided analyzable data in 100%, whereas the visual assessment of gray-scale images was possible only in 90%. Thus, in patients with suspected RCA narrowing, pulse-wave Doppler tissue sampling during DSE was able to diagnose significant RCA narrowing. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00029149
Volume :
81
Issue :
12
Database :
Academic Search Index
Journal :
American Journal of Cardiology
Publication Type :
Academic Journal
Accession number :
787391
Full Text :
https://doi.org/10.1016/S0002-9149(98)00208-2