Back to Search Start Over

Borehole resistance and vertical temperature profiles in coaxial borehole heat exchangers

Authors :
Beier, Richard A.
Acuña, José
Mogensen, Palne
Palm, Björn
Source :
Applied Energy. Feb2013, Vol. 102, p665-675. 11p.
Publication Year :
2013

Abstract

Abstract: Ground source heat pump systems are often coupled to the ground by circulating a fluid through vertical Borehole Heat Exchangers (BHEs). The design of a system requires estimates of the ground thermal conductivity and the borehole thermal resistance, which are usually determined by an in situ thermal response test on a completed borehole. The usual test interpretation methods average the inlet and outlet fluid temperatures and use this mean temperature as the average temperature along the borehole length. This assumption is convenient but does not strictly apply. For a coaxial heat exchanger this paper develops an analytical model for the vertical temperature profiles, which can be used instead of the mean temperature approximation to estimate borehole resistance. The model is verified with measured temperatures on a BHE, where an optical technique allows continuous measurements along a coaxial borehole during a distributed thermal response test. A sensitivity study shows that the proposed method corrects errors in the mean temperature approximation, which overestimates the borehole resistance in a coaxial borehole. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
03062619
Volume :
102
Database :
Academic Search Index
Journal :
Applied Energy
Publication Type :
Academic Journal
Accession number :
83933806
Full Text :
https://doi.org/10.1016/j.apenergy.2012.08.007